10 – Performing Diagnostics
Viewing the Diagnostic Test Results
10-6 FS0054601-00 E
Q
10.4
Viewing the Diagnostic Test Results
The test results section of the Diagnostics tabbed page displays the results of a
test run (see figure 10-2). The Test Status column indicates whether the test passed
or failed. The remaining information pertains to error counters.
Figure 10-2. Diagnostic Test Results Section
This section discusses:
Loopback test results (see section 10.4.1)
Read/write buffer test results (see section 10.4.2)
10.4.1
Loopback Test Results
The Loopback Test Results section provides the following information:
Tests Status. Whether the test passed or failed. The possible values:
Success. The test passed.
Error. CRC, disparity, or frame length errors occurred.
Failed. An error occurred when attempting to issue a command.
Loop down. The loop is down.
CRC Error. Number of CRC errors
Disparity Error. Number of disparity errors
Frame Length Error. Number of frame length errors