Qlogic QME7342 Guía de usuario Pagina 192

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 284
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 191
BSRP Configuration
QLogic SRP Configuration
B-16 IB0054606-02 A
On the VIO hardware side, the following needs to be ensured:
The target device is discovered and configured for each of the ports that is
involved in the failover.
The SRP Initiator is discovered and configured once for each different
initiatorExtension.
Each map should use a different Configured Device, e.g Configured Device
1 has the Target being discovered over FC Port 1, and Configured Device 2
has the Target being discovered over FC Port 2.)
Failover Configuration File 3: Failing over from a port on a
VIO hardware card to a port on a different VIO hardware card
within the same Virtual I/O chassis
session
begin
card: 0 (InfiniServ HCA card number)
port: 1 (InfiniServ HCA port number)
targetIOCProfileIdString: "FVIC in Chassis <FRUChassisGUID>,
<Slot1>, <IOC>"
initiatorExtension: 1
end
session
begin
card: 0 (InfiniServ HCA card number)
port: 1 (InfiniServ HCA port number)
targetIOCProfileIdString: "FVIC in Chassis <FRUChassisGUID>,
<Slot2>, <IOC>" (Slot number differs to indicate a different
VIO card)
initiatorExtension: 1 (Here the initiator extension can be the
same as in the previous definition, because the SRP map is
being defined on a different FC gateway card)
end
adapter
begin
description: “FC Port Failover”
end
Vista de pagina 191