4–Installation
Verify Equipment Connectivity
51031-00 A 4-11
4. When the LUNs have been created and all zoning is complete, use the
management interface to add the Converged Network Adapter Fibre
Channel WWNs and iSCSI initiators to your storage so that the servers can
discover the LUNs. Figure 4-6 shows an example of the discovered FCoE
Converged Network Adapters and the created initiator groups on a NetApp
Filer after zoning is complete.
Figure 4-6. NETApp Zone Validation
5. Reboot the servers to discover the assigned LUNs.
6. Verify that server operating system and SANsurfer management application
can discover the assigned LUNs (Figures 4-7 and 4-8).