14 Dell Compellent Using Storage Center with FCoE and Linux
3: Return to Previous Menu
Note: 0 to return to Main Menu
Enter Selection:
In the output shown above, the “Online” postfix behind each HBA Port identifier represents that the CNA
has negotiated with the network and can be considered to be in a “Link Up” state in the attached FCoE
network. In the output below, further HBA details are shown.
--------------------------------------------------------------------------------
HBA Instance 0: QLE8152 Port 1 WWPN 21-00-00-C0-DD-1B-A0-E1 PortID 31-00-0A
--------------------------------------------------------------------------------
------------------------------------------------------
General Info
------------------------------------------------------
MPI FW Version : 01.40.03
EDC FW Version : 01.08.00
VN Port MAC Address : 0E:FC:00:31:00:0A
VLAN ID : 300
Max Frame Size : 2500 (Baby Jumbo)
Addressing Mode : FPMA
------------------------------------------------------
Hit <RETURN> to continue:
The CNA will additionally identify the VLAN available to it, with most switching vendors, this means the
port can be easily correlated to its associated VLAN to fabric mapping. The TLV settings for a CNA will
expose any DCB policies inherited from the FCoE network as shown below.
TLV Menu
HBA Instance 0 (QLE8152 Port 1) : Online
ENode MAC Addr: 00:C0:DD:1B:A0:E1
WWPN : 21-00-00-C0-DD-1B-A0-E1
Desc : QLE8152 QLogic PCI Express to 10 GbE Dual Channel CNA (FCoE)