18 Dell Compellent Using Storage Center with FCoE and Linux
172.16.26.4:3260,0 iqn.2002-03.com.compellent:5000d31000006924
Now that the targets have been discovered, login requests can be sent, which will make the iSCSI initiator
iSCSI iqn a visible object on the Storage Center.
# iscsiadm -m node --login
Logging in to [iface: default, target: iqn.2002-
03.com.compellent:5000d31000006922, portal: 172.16.26.4,3260]
Logging in to [iface: default, target: iqn.2002-
03.com.compellent:5000d31000006923, portal: 10.10.140.4,3260]
Logging in to [iface: default, target: iqn.2002-
03.com.compellent:5000d31000006925, portal: 10.10.140.4,3260]
Logging in to [iface: default, target: iqn.2002-
03.com.compellent:5000d31000006924, portal: 172.16.26.4,3260]
Login to [iface: default, target: iqn.2002-03.com.compellent:5000d31000006922,
portal: 172.16.26.4,3260] successful.
Login to [iface: default, target: iqn.2002-03.com.compellent:5000d31000006923,
portal: 10.10.140.4,3260] successful.
Login to [iface: default, target: iqn.2002-03.com.compellent:5000d31000006925,
portal: 10.10.140.4,3260] successful.
Login to [iface: default, target: iqn.2002-03.com.compellent:5000d31000006924,
portal: 172.16.26.4,3260] successful.
From the Storage Center interface, the Server Object can now be created. During the creation, notice the
two IPs listed, this means the Storage Centers has observed logins from the listed iSCSI iqn from two
unique and distinct subnets, representing a healthy multipath environment.
Comentarios a estos manuales