Chapter 3. Implementing the INRANGE FC/9000 Fibre Channel Director 225
To enable all ports to attach loop devices, select the specific director in the
navigation tree of IN-VSN and click Auto Sense Arbitrated Loop Enable in the
Director menu, as shown in Figure 3-43.
Figure 3-43 IN-VSN: Enabling Auto Sense Arbitrated Loop for the entire director
Be aware that this change could interrupt in-progress I/O on ports. Therefore,
use this procedure only if you are sure about the consequences of the warning
given in the confirmation window, as illustrated in Figure 3-44.
Figure 3-44 IN-VSN: Confirming loop enabling for the entire director
Loop ports in a name server table
Once you have a port enabled to sense Arbitrated Loop ports and there is
actually a loop port attached, then you can verify that it has been recognized
correctly by reading the name server table.
Public loop ports are displayed as NL_Ports (Node Loop), whereas private loop
ports are displayed as TL_Ports (translative loop).