Qlogic QLA4010 Guía de instalación Pagina 1

Busca en linea o descarga Guía de instalación para Barebones Pc / Estación De Trabajo Qlogic QLA4010. Qlogic QLA4010 Installation guide Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 118
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
EMC Corporation
Corporate Headquarters:
Hopkinton, MA 01748 -9103
1
-508 -435 -1000
www.emc.com
EMC Fibre Channel and iSCSI with
QLogic Host Bus Adapters in the
Windows Environment
P/N 300-001-164
REV A09
Vista de pagina 0
1 2 3 4 5 6 ... 117 118

Indice de contenidos

Pagina 1 - Windows Environment

EMC CorporationCorporate Headquarters:Hopkinton, MA 01748 -91031-508 -435 -1000www.emc.comEMC Fibre Channel and iSCSI withQLogic Host Bus Adapters in

Pagina 2

EMC Fibre Channel with QLogic HBAs in the Windows Environment xTables

Pagina 3 - Contents

22-24EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentPlanning, Miscellaneous Procedures, and Troubleshooting10. Execute the fol

Pagina 4 - Troubleshooting

2Procedure for Replacing a QLogic HBA in Stratus ftServers without Rebooting2-25Planning, Miscellaneous Procedures, and Troubleshooting10. Run symmask

Pagina 5

22-26EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentPlanning, Miscellaneous Procedures, and TroubleshootingSet the HBA FC-AL L

Pagina 6

2Set the HBA FC-AL Loop ID2-27Planning, Miscellaneous Procedures, and Troubleshooting8. Press ESC to return to the Configuration Settings menu.9. Pres

Pagina 7

22-28EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentPlanning, Miscellaneous Procedures, and TroubleshootingSpecial Instruction

Pagina 8

2Special Instructions for CLARiiON CX200-Series Direct-Connect Dual-Host Clustering Configurations2-29Planning, Miscellaneous Procedures, and Troubles

Pagina 9

22-30EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentPlanning, Miscellaneous Procedures, and TroubleshootingUnderstanding Persi

Pagina 10

2Understanding Persistent Binding in a Fabric Environment2-31Planning, Miscellaneous Procedures, and Troubleshooting\\.\PHYSICALDRIVE1, and \\.\PHYSIC

Pagina 11

22-32EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentPlanning, Miscellaneous Procedures, and TroubleshootingThe next figure sho

Pagina 12 - AVANT GARDE Keystrokes

2Problems and Solutions2-33Planning, Miscellaneous Procedures, and TroubleshootingProblems and SolutionsProblem 1Error Message ID: 51 in event viewer

Pagina 13

EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentxiPrefaceAs part of an effort to improve and enhance the performance and capabi

Pagina 14

22-34EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentPlanning, Miscellaneous Procedures, and TroubleshootingSolution Upgrade to

Pagina 15 - Configuration

2Problems and Solutions2-35Planning, Miscellaneous Procedures, and TroubleshootingProblem 7When using SANsurfer 2.0.25 to update to BIOS 1.4x, you rec

Pagina 16 - How this Guide Works

22-36EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentPlanning, Miscellaneous Procedures, and TroubleshootingKnown IssuesBe awar

Pagina 17

Third-Party SoftwareA-1AInvisible Body TagThis appendix contains additional information about third-party software used with Windows hosts.◆ QLogic SA

Pagina 18

AA-2 EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentThird-Party SoftwareQLogic SANsurfer SANblade ManagerStratus ftServers are

Pagina 19 - STOP: 0X0000007B

AQLogic SANsurfer SANblade ManagerA-3Third-Party SoftwareSANsurfer Version HistorySANsurfer versions include:◆ 2.0.21 — Initial ReleaseThe SANsurfer s

Pagina 20

AA-4 EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentThird-Party Software

Pagina 21 - Figure 2- HBA edge connecters

EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows Environmenti-1CCLARiiON storage 1-5FftServers, Stratus 1-5HHBA, installing 1-4Ppersiste

Pagina 22 - PCI Express slots aligned

EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows Environmenti-2Index

Pagina 23

xiiEMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentPrefaceConventions Used inThis GuideEMC uses the following conventions for n

Pagina 24

EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentxiiiPrefaceWhere to Get Help For questions about technical support, call your l

Pagina 25

xivEMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentPreface

Pagina 26 - 2322ipx.bin

Installation and Configuration1-11Invisible Body TagThis document describes the procedures for installing an EMC-approved QLogic host bus adapter (HBA

Pagina 27

11-2EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentInstallation and ConfigurationHow this Guide WorksIn an effort to simplify

Pagina 28 - QLogic Banner

1How this Guide Works1-3Installation and ConfigurationFigure 1-1 Installation and Configuration OverviewCreate a floppy diskwith EMC-Approveddriver, f

Pagina 29 - Configuration Settings Window

11-4EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentInstallation and ConfigurationInstalling the HBA into Your ServerFollow the

Pagina 30 - Adapter Settings Window

1Installing the HBA into Your Server1-5Installation and Configuration4. Label each cable to identify the HBA and the storage/switch/hub port to which

Pagina 31

EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentiiCopyright © 2001–2005 EMC Corporation. All rights reserved.Published: Decembe

Pagina 32

11-6EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentInstallation and Configurationdenote the type of voltage is provided by the

Pagina 33 - Enter

1Installing the HBA into Your Server1-7Installation and ConfigurationFigure 1-3 Figure 2- HBA edge connectersPCI-X (or PCI Extended) slots increase th

Pagina 34 - Fast!Util Options Window

11-8EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentInstallation and ConfigurationFigure 1-4 PCI Express slotsFigure 1-5 shows

Pagina 35 - QLogic BIOS Banner Screen

1Installing the HBA into Your Server1-9Installation and ConfigurationQLogic offers HBAs for each bus/slot type available. Table 1-1 shows each of the

Pagina 36 - Firmware Boot Manager Menu

11-10EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentInstallation and ConfigurationBooting from the External Storage ArrayIf yo

Pagina 37 - Device Mapping Table

1Booting from the External Storage Array1-11Installation and ConfigurationNote: NVRAM is short for Non-Volatile RAM. This is a special portion of mem

Pagina 38 - QLogic Directory

11-12EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentInstallation and Configuration7. For QLA236x/QLE236x execute the following

Pagina 39

1Booting from the External Storage Array1-13Installation and Configuration◆ In direct-attach configurations, an HBA has a physical connection to the a

Pagina 40

11-14EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentInstallation and ConfigurationLegacy (x86 and most EM64T-based servers) bo

Pagina 41 - QLogic efiutil all Upgrade

1Booting from the External Storage Array1-15Installation and ConfigurationFigure 1-7 Main Fast!Util Options WindowSelect Configuration Settings from t

Pagina 42 - Utililty Install

EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentiiiPreface...

Pagina 43

11-16EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentInstallation and ConfigurationSelect Adapter Settings from the Configurati

Pagina 44 - Driver Handle Numbers

1Booting from the External Storage Array1-17Installation and ConfigurationFigure 1-11 Selectable Boot Settings WindowSelectable Boot is Disabled by de

Pagina 45

11-18EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentInstallation and ConfigurationFigure 1-12 Select Fibre Channel Device Wind

Pagina 46 - Connection Option

1Booting from the External Storage Array1-19Installation and ConfigurationFor example, Figure 1-13 shows that LUN 17 is masked to the HBA. The LUN is

Pagina 47 - Options Set

11-20EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentInstallation and ConfigurationFigure 1-14 Selectable Boot Settings WindowP

Pagina 48 - Example blkD as Array Port

1Booting from the External Storage Array1-21Installation and ConfigurationTo exit the Fast!UTIL configuration utility, select Exit Fast!UTIL and press

Pagina 49

11-22EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentInstallation and ConfigurationFigure 1-18 Firmware Boot Manager Menu

Pagina 50

1Booting from the External Storage Array1-23Installation and ConfigurationThe EFI shell will be opened, and the Device Mapping Table may be listed by

Pagina 51 - Windows Setup with F6 Prompt

11-24EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentInstallation and ConfigurationBefore loading the QLogic EFI boot code/driv

Pagina 52

1Booting from the External Storage Array1-25Installation and ConfigurationThe directory listing should contain the QLogic EFI boot code/utility which

Pagina 53

EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentivContentsChapter 2 Planning, Miscellaneous Procedures, and TroubleshootingInst

Pagina 54 - Existing Partitions

11-26EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentInstallation and ConfigurationIf the firmware is listed as a series of zer

Pagina 55

1Booting from the External Storage Array1-27Installation and ConfigurationFigure 1-23 QLogic efiutil all UpgradeThe utility will upgrade EFI boot code

Pagina 56

11-28EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentInstallation and Configurationpage 1-24, "2312" refers to the ch

Pagina 57 - Pre-installation Guidelines

1Booting from the External Storage Array1-29Installation and ConfigurationThe appropriate non-volatile RAM (NVRAM) settings must now be loaded onto th

Pagina 58 - Driver Installation/

11-30EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentInstallation and ConfigurationFigure 1-26 QLogic HBA Instances with Specif

Pagina 59

1Booting from the External Storage Array1-31Installation and ConfigurationFind the driver handle numbers which correspond to those listed for the QLog

Pagina 60 - SANsurfer Driver Selection

11-32EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentInstallation and ConfigurationFigure 1-30 Edit Adapter SettingsBy default,

Pagina 61

1Booting from the External Storage Array1-33Installation and ConfigurationIn FC-SW environments, "Point To Point" is the appropriate setting

Pagina 62

11-34EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentInstallation and ConfigurationPress Enter to return to the EFI shell. Typ

Pagina 63

1Installing a RAMDISK under the EFI Shell1-35Installation and ConfigurationInstalling a RAMDISK under the EFI ShellIntel provides an EFI toolkit on th

Pagina 64 - Procedures

vEMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentContentsAppendix A Third-Party SoftwareQLogic SANsurfer SANblade Manager ...

Pagina 65 - SANsurfer HBA Install Wizard

11-36EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentInstallation and ConfigurationInstalling the Windows Operating SystemThis

Pagina 66 - Next to run the test

1Installing the Windows Operating System1-37Installation and ConfigurationIf you do not press F6 in time to add the drivers, restart the server and tr

Pagina 67

11-38EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentInstallation and ConfigurationFigure 1-36 Specifying a Driver for your HBA

Pagina 68 - Show SAN

1Installing the Windows Operating System1-39Installation and ConfigurationFigure 1-37 HBA Selection Screen5. Select the appropriate boot HBA and press

Pagina 69 - QLogic Advanced Utilities

11-40EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentInstallation and Configuration7. Read the license agreement. (Press Pg Dn

Pagina 70

1Installing the Windows Operating System1-41Installation and Configuration8. If you are installing an operating system for the first time, highlight U

Pagina 71 - Utilities Tabbed Page

11-42EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentInstallation and ConfigurationIf you are reinstalling Windows, the setup s

Pagina 72

1Installing HBA Driver and Software Utilities1-43Installation and ConfigurationInstalling HBA Driver and Software UtilitiesTo use EMC storage array di

Pagina 73 - SANsurfer Icon

11-44EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentInstallation and Configuration3. Select EMC under OEM models.4. Select the

Pagina 74 - Connect to the Host

1Installing HBA Driver and Software Utilities1-45Installation and ConfigurationFigure 1-40 SANsurfer Driver Install Wizard Wecome 3. Click Next to sta

Pagina 75

EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentviContents

Pagina 76

11-46EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentInstallation and ConfigurationFigure 1-41 SANsurfer Driver SelectionThis w

Pagina 77 - Procedures, and

1Installing HBA Driver and Software Utilities1-47Installation and Configuration4. Click Next to continue. A message similar to the following will app

Pagina 78

11-48EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentInstallation and ConfigurationFigure 1-43 SANsurfer Java Agent Service Mes

Pagina 79

1Installing HBA Driver and Software Utilities1-49Installation and ConfigurationFigure 1-44 SANsurfer Driver Installation Completed Successfully7. A &q

Pagina 80

11-50EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentInstallation and ConfigurationFigure 1-45 SANsurfer Driver Installation Co

Pagina 81

1Installing HBA Driver and Software Utilities1-51Installation and ConfigurationFigure 1-46 SANsurfer HBA Install Wizard2. Select the HBAs to be tested

Pagina 82 - Download Firmware Dialog

11-52EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentInstallation and ConfigurationFigure 1-47 SANsurfer Install Wizard Attach

Pagina 83

1Installing HBA Driver and Software Utilities1-53Installation and ConfigurationFigure 1-48 SANsurfer HBA Installation Diagnostics Results4. The next

Pagina 84

11-54EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentInstallation and ConfigurationShow SANFigure 1-49 shows the SAN tree.Figur

Pagina 85

1QLogic Advanced Utilities1-55Installation and ConfigurationQLogic Advanced UtilitiesUpdating QLogic Firmware/BIOS and Applying NVRAM SettingsYou can

Pagina 86

EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows Environmentvii1-1 Installation and Configuration Overview ...

Pagina 87

11-56EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentInstallation and ConfigurationUpdating the Flash BIOS Using SANsurfer FC H

Pagina 88

1QLogic Advanced Utilities1-57Installation and ConfigurationFigure 1-50 Utilities Tabbed PageThe identifying information displays:• Host. Name of the

Pagina 89

11-58EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentInstallation and Configurationacceptable flash BIOS file for the adapter,

Pagina 90

1Verifying Connectivity to the Storage Array1-59Installation and ConfigurationVerifying Connectivity to the Storage ArrayOn a Windows 2000/Windows Ser

Pagina 91 - BladeServer Restrictions

11-60EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentInstallation and ConfigurationFigure 1-52 Connect to the Host6. In the &qu

Pagina 92

1Verifying Connectivity to the Storage Array1-61Installation and ConfigurationFigure 1-53 SANsurfer, SANsurfer FC HBA Manager

Pagina 93 - Driver Revision

11-62EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentInstallation and Configuration

Pagina 94 - Compmgmt.msc and press Enter

Planning, Miscellaneous Procedures, and Troubleshooting2-12Invisible Body TagThis appendix contains information on planning, miscellaneous procedures,

Pagina 95 - 2003 Host

22-2EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentPlanning, Miscellaneous Procedures, and TroubleshootingInstalling and Confi

Pagina 96

2Installing and Configuring the QLogic QLA4010 iSCSI HBA (TOE)2-3Planning, Miscellaneous Procedures, and TroubleshootingFigure 2-1 SANsurfer iSCSI HBA

Pagina 97 - Windows 2000

EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentviiiFigures1-31 Connection Option ...

Pagina 98

22-4EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentPlanning, Miscellaneous Procedures, and TroubleshootingFigure 2-2 SANsurfer

Pagina 99

2Installing and Configuring the QLogic QLA4010 iSCSI HBA (TOE)2-5Planning, Miscellaneous Procedures, and Troubleshootingsteps:1. Ping successfully to

Pagina 100

22-6EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentPlanning, Miscellaneous Procedures, and TroubleshootingFigure 2-4 Download

Pagina 101

2Installing and Configuring the QLogic QLA4010 iSCSI HBA (TOE)2-7Planning, Miscellaneous Procedures, and TroubleshootingFigure 2-5 SANsurfer iSCSI HBA

Pagina 102 - Set the HBA FC-AL Loop ID

22-8EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentPlanning, Miscellaneous Procedures, and TroubleshootingTo configure your iS

Pagina 103

2Installing and Configuring the QLogic QLA4010 iSCSI HBA (TOE)2-9Planning, Miscellaneous Procedures, and TroubleshootingYou can add as many targets as

Pagina 104

22-10EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentPlanning, Miscellaneous Procedures, and TroubleshootingAfter CHAP settings

Pagina 105

2Booting from SAN with QLogic QLA4010 and Microsoft Initiator2-11Planning, Miscellaneous Procedures, and TroubleshootingBooting from SAN with QLogic Q

Pagina 106

22-12EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentPlanning, Miscellaneous Procedures, and TroubleshootingThis can be accompl

Pagina 107

2Boot-from-SAN Configuration Restrictions2-13Planning, Miscellaneous Procedures, and TroubleshootingBoot-from-SAN Configuration RestrictionsRefer to t

Pagina 108 - PHYSICALDRIVE8

EMC Fibre Channel with QLogic HBAs in the Windows Environmentix1-1 EMC-supported QLogic HBAs ...

Pagina 109 - Problems and Solutions

22-14EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentPlanning, Miscellaneous Procedures, and TroubleshootingSetting Up External

Pagina 110 - Problem 6

2BladeServer Restrictions2-15Planning, Miscellaneous Procedures, and TroubleshootingBladeServer Restrictions Table 2-1 describes QLogic software suppo

Pagina 111 - Problem 8

22-16EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentPlanning, Miscellaneous Procedures, and TroubleshootingEditing the Windows

Pagina 112 - Known Issues

2Manually Installing the HBA Driver – Advanced Users2-17Planning, Miscellaneous Procedures, and TroubleshootingManually Installing the HBA Driver – Ad

Pagina 113 - Third-Party Software

22-18EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentPlanning, Miscellaneous Procedures, and Troubleshooting◆ STORPort 9.1.0.15

Pagina 114 - Manager Software or Agents

2Manually Installing the HBA Driver – Advanced Users2-19Planning, Miscellaneous Procedures, and TroubleshootingHBAs. If this occurs, the HBA will alre

Pagina 115 - SANsurfer Version

22-20EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentPlanning, Miscellaneous Procedures, and Troubleshooting1. Boot the host (i

Pagina 116

2Manually Installing the HBA Driver – Advanced Users2-21Planning, Miscellaneous Procedures, and Troubleshootinghttp://h200005.www2.hp.com/bc/docs/supp

Pagina 117

22-22EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows EnvironmentPlanning, Miscellaneous Procedures, and TroubleshootingExtended Error Logg

Pagina 118

2Procedure for Replacing a QLogic HBA in Stratus ftServers without Rebooting2-23Planning, Miscellaneous Procedures, and TroubleshootingProcedure for R

Comentarios a estos manuales

Sin comentarios